OS series Double Suction Split Case Pump / construction water supply pump
【Uses】
OS pump for single-stage double suction in the open centrifugal pump. Mainly applicable to the water plant, air conditioning and recycling water, construction water supply, irrigation, drainage pumping stations, power plants, industrial water supply systems, fire systems, shipbuilding and other industries to transport liquid occasions.
【Product description】
The OS pump is a single stage double suction open centrifugal pump. Mainly applicable to the water plant, air conditioning and recycling water, construction water supply, irrigation, drainage pumping stations, power plants, industrial water supply systems, fire systems, shipbuilding and other industries to transport liquid, meet the standard GB5657.
【Structural features】
【Model meaning】
OS150-360 (i) GA
OS: Double suction in the volute centrifugal pump
150: pump outlet diameter of 150mm
360: impeller nominal diameter of 360mm
(I): expansion type
G: high speed
A: The first cut impeller
Product overview:
The SOW-type volute single-stage double suction centrifugal pump is the introduction of advanced technology to produce high-performance pumps. The pump can be used to provide pumps that meet the needs of the user at any point of operation as required by the use of the prototype impeller and the modified impeller and its cutting, the broad spectrum of spectrum, the use of high efficiency, within the spectral performance range. The pump adopts the hydraulic model of self-balancing axial force and radial force at home and abroad. The performance is stable, the efficiency is high, the structure is compact, the vibration is small, the pump pressure is high and the installation and maintenance is convenient.
Performance and advantages
Compact structure, small footprint, small axial size, low vibration noise, rotor parts, axial size is short and good rigidity, the pump shaft with high precision bearing support.
Application scope
Water plant pressurized water, air conditioning and recycling water, fire protection systems, industrial water supply systems, shipbuilding industry, oil refining industry.
Features
Factories Double Suction Split Case Pump inlet diameter of 250mm
Uses:
The double suction pump is also known as a single-stage double suction centrifugal pump, the main feature for the transmission medium flow, mainly for factories, cities, Power stations, water conservancy projects, irrigation and other drainage or water supply pump. The transport of solid particles can not exceed the diameter of 10mm, the content can not exceed 5%.
【Product description】
Double suction in the pump is also known as a single-stage double suction centrifugal pump, the main feature of the transmission medium flow, head, in the open pump operation principle: impeller installed in the pump shell and fastened to the pump shaft On the pump shaft directly driven by the motor. There is a liquid suction in the center of the pump housing connected to the suction pipe.
Wei-pump production of the double suction pump is a horizontal centrifugal pump, the type of pump with a flow range than the IS-wide, the head is not very high characteristics, mainly for factories, cities, power plants, water conservancy projects, Farmland irrigation and other drainage or water supply pump. The transport of solid particles can not exceed the diameter of 10mm, the content can not exceed 5%. Pump delivery medium temperature can not exceed 80 ℃, the inlet pressure can not exceed 0.6Mpa.
【Structure Introduction】
The pump suction and discharge are in the pump under the axis of the axis, the horizontal direction and the axis into a vertical position, the pump shell open, maintenance without disassembly of water, discharge pipes and motors (or other prime movers) from the joint Shaft to the direction of the pump looked, the pump are clockwise rotation, the pump inlet on the right. Such as according to the user special order needs can also be changed counterclockwise rotation.
The main components of the pump, pump cover, impeller, shaft, double suction ring, sleeve, bearings and so on. In addition to the shaft material for high-quality carbon steel, the rest are made of cast iron. But according to the needs of the user axis can be changed to stainless steel, stainless steel and other material pump body and pump cover can also be.
The pump body and the pump cover constitute the impeller working chamber, in the inlet and outlet of the flange on the installation of the vacuum gauge and pressure gauge pipe screw hole. The impeller is calibrated by static balance, fixed with the sleeve and the sleeve nuts on both sides. The axial position can be adjusted by the sleeve nut. The axial force of the impeller is balanced with its symmetrical arrangement of the blades, and there may be some remaining The axial force is the bearing of the coaxial end. The pump shaft is supported by two single row radial ball bearings, which are mounted on the bearing body at both ends of the pump body and lubricated with butter. The double suction seal ring is used to reduce the water in the pump water chamber.
The pump is directly driven by the motor through the coupling, the shaft seal is a soft packing seal, and the other material and mechanical seal can be used according to the different media. In order to cool the lubricating seal chamber and prevent the air from leaking into the pump, there is a water seal ring between the packing, and the water pump works with a small amount of high-pressure water flowing through the water seal tube into the packing chamber.
【Model meaning】
double suction in the pump model with the S / SH type pump
250S-65A
250: pump inlet diameter of 250mm
S: single stage double suction horizontal centrifugal pump
65: head for 65m
A: Impeller first cut
10SH-13A
10: 1/25 of the suction diameter (mm) (the pump suction diameter is 250 mm)
SH: single stage double suction horizontal centrifugal pump
13: pump than the number of revolutions of 1/10
A: Impeller first cut
Power stations Double Suction Split Case Pump SOW series ISO 9001
【Uses】
SOW series single-stage double suction pump is mainly for the delivery temperature of not more than 105 ℃ water or physical and chemical properties similar to the liquid water. It is suitable for the transportation of liquids such as waterworks, drainage pumping stations, power stations, construction water supply, irrigation, air conditioning and recycling water, hot water circulation for heating, industrial water supply system, fire protection system, shipbuilding industry (general liquid)
【Product description】
SOW series of single-stage double suction pump level in the open volute centrifugal pump, the main transport temperature is not higher than 105 ℃ water or physical and chemical properties similar to the water liquid. It is suitable for the transportation of liquids such as waterworks, drainage pumping stations, power stations, construction water supply, irrigation, air conditioning and recycling water, hot water circulation for heating, industrial water supply system, fire protection system, shipbuilding industry (general liquid)
【Structural features】
【Model meaning】
SOW150-365 (I) A (B, C)
SOW: volute type in the open double suction pump
150: Pump outlet diameter (mm)
365: Impeller nominal diameter (mm)
(I): Expand the flow type
A (B, C): Impeller is cut by the first (second, third) times
Product description】
S, SH-type open single-stage double suction centrifugal pump, (referred to as S, SH-type in the pump), the Department of a new single-stage double suction horizontal centrifugal pump products. The pump has a highly efficient energy-saving, the wide range of applications, axial force balance, long life, in the open structure, easy maintenance, fast. S, SH-type open single-stage dual-suction centrifugal pump for conveying a variety of clean or with trace particles of neutral or weak corrosive liquid.
【Range of application】
The pump is suitable for use in waterworks, irrigation, drainage pumping stations, power stations, industrial water supply systems, air conditioning systems, fire protection systems, and shipbuilding industries. It is also suitable for general use in the oil refining industry.
【Model meaning】
10SH-13A
10: 1/25 of the suction diameter (mm) (the pump suction diameter is 250 mm)
SH: single stage double suction horizontal centrifugal pump
13: pump than the number of revolutions of 1/10
A: Impeller first cut
Contact Person: Mr.
Tel: 86-311-80660278